Related Experiment Video
Updated: Jan 18, 2026

Author Spotlight: Development and Evaluation of a Standardized Rat Model for Calvarial Suture-Bony Composite Defects
Published on: May 10, 2024
Analysis of radiological changes using computed tomography after treatment with suture-button fixation in syndesmosis
Bi O Jeong1, Jin Hyung Kim1, Min Gyu Kyung1
1Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 23 Kyunghee-daero, Dongdaemun-gu, Seoul 02447, Republic of Korea.
Background:
This study investigated radiological changes in syndesmotic injuries after suture-button fixation, from the immediate postoperative period to the resumption of daily activities.
Methods:
We retrospectively analyzed 38 patients who underwent syndesmosis fixation using a suture-button. Anterior difference (AD), posterior difference (PD), fibular translation (FT), and fibular rotation (FR) were measured on computed tomography scans and compared across time points and with the contralateral side.
Results:
AD and PD significantly increased preoperatively, decreased immediately postoperatively, and were slightly increased or maintained at 6 months, resembling the normal side. FT showed no significant changes over time. FR decreased immediately after surgery and slightly increased at 6 months, approaching values of the contralateral side.
Conclusions:
Suture-button fixation initially over-narrowed the syndesmosis compared to the normal side. However, with weightbearing and daily activities, the overcorrected syndesmosis gradually adjusted to resemble the uninjured side.
Level Of Evidence:
III.