Related Experiment Video
Updated: Sep 19, 2025

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
A Novel Approach for Localizing Non-Sustained Atrial Arrhythmias: Atrial Pace-Mapping With Automatic Intracardiac
Evgeny Lian1,2, Vera Maslova1, Sven Willert1
1Department of Internal Medicine III (Cardiology and Intensive Care Medicine), University Hospital Schleswig-Holstein (UKSH), Kiel, Germany.
Introduction:
Ventricular pace mapping is an established tool to identify the origin of non-inducible arrhythmias by analyzing the paced QRS morphology of the surface electrocardiogram (ECG). Using the same approach for atrial pace mapping (APM) was shown to be suboptimal, as accurate assessment of P wave morphology can be limited. We present a novel approach for APM using an automatic ECG pattern-matching algorithm with intracardiac unipolar signals (aICPM).
Methods And Results:
Forty-five consecutive patients presenting with non-sustained atrial tachycardia (nsAT) or non-pulmonary vein (PV) triggers were prospectively included. APM using aICPM was performed with six biatrial unipolar signals to create score maps. Ablation targeted sites with the best intracardiac pattern similarity. The primary endpoint was defined as successful localization and non-inducibility of the arrhythmia. Secondary endpoint was defined as freedom from AF/AT during the follow-up. APM with aICPM successfully identified specific areas with high intracardiac pattern similarity in all patients. The median time required to create a score map was 5.0 (IQR 3.3; 6.3) minutes, with 106 (IQR 77; 155) points per map. Radiofrequency ablation was performed successfully in all but two patients, with a median ablation time of 134 (IQR 75; 180) seconds and an ablation area of 2.0 (IQR 1.1; 2.3) cm². Two patients underwent ethanol ablation of the vein of Marshall. All cases achieved non-inducibility of the arrhythmia. During a follow-up of 5.9 ± 1.87 months, five patients experienced arrhythmia recurrence.
Conclusion:
This novel approach rapidly and accurately identifies the origin of atrial arrhythmias by creating atrial pacemaps using an automated ECG pattern-matching algorithm, which processes intracardiac unipolar signals.
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Mechanism of Cardiac Arrhythmias
Dysrhythmias II: Classification of Tachyarrhythmias

