Performance of Oxygen Flow Meters From Different Manufacturers: An Analysis of Accuracy

Amanda R Pagliocchi1,2, Gerson F Souza1,3, Josy Davidson1

  • 1Ms. Pagliocchi, Dr. Souza, Ms. Davidson, Prof. Gazzotti, Dr. Nascimento, and Prof. Jardim are affiliated with Pulmonary Rehabilitation Unit of Escola Paulista de Medicina (EPM)/Federal University of São Paulo (Unifesp), São Paulo, Brazil.

Respiratory Care
|June 4, 2025
PubMed
Abstract

No abstract available in PubMed .

Related Concept Videos

Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
1.2K
Special considerations while measuring oxygen saturation01:19

Special considerations while measuring oxygen saturation

Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
899
Pulse Oximetry01:24

Pulse Oximetry

Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.3K
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
818
Oxygen Delivering System I: Nasal Cannula and Face Mask01:26

Oxygen Delivering System I: Nasal Cannula and Face Mask

The human body requires oxygen to function, and when the natural process of respiration is hindered, external devices, including the following, are needed to help deliver this vital gas.
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
1.5K
Assessment of Diffusion and Perfusion01:17

Assessment of Diffusion and Perfusion

Understanding and evaluating diffusion and perfusion is critical in assessing a patient's respiratory and circulatory health. These processes play key roles in maintaining the body's internal environment, ensuring that tissues receive adequate oxygen while waste products are efficiently removed.
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
1.6K