Related Experiment Video
Updated: Jul 11, 2026

Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures
Published on: October 9, 2012
Momentum microscopy with combined hemispherical and time-of-flight electron analyzers at the soft X-ray beamline I09
Matthias Schmitt1, Deepnarayan Biswas2, Olena Tkach3
1Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom; Physikalisches Institut and Würzburg-Dresden Cluster of Excellence ct.qmat, Julius-Maximilians-Universität, D-97074 Würzburg, Germany.
Abstract:
The three-dimensional recording scheme of time-of-flight momentum microscopes (ToF-MMs) is advantageous for fast mapping of the photoelectron distribution in (E,k) parameter space over the entire Brillouin zone. However, the 2 ns pulse period of most synchrotrons is too short for pure ToF photoelectron spectroscopy. The use of a hemispherical analyzer (HSA) as a pre-filter allows ToF-MM at such high pulse rates. The first HSA & ToF hybrid MM is operated at the soft X-ray branch of beamline I09 at the Diamond Light Source, UK. The photon energy ranges from 105 eV to 2 keV, with circular polarization available for hν ≥ 145 eV. The HSA reduces the transmitted energy band to typically 0.5 eV, which is then further analyzed by ToF recording. In initial experiments, the overall efficiency gain when switching from the standard 2D (kx,ky) mode to the 3D (kx,ky,Ekin) hybrid mode was about 24. This value is determined by the number of resolved kinetic energies (here 12) and the transmission gain of the electron optics due to the high pass energy of the HSA in hybrid mode (Epass up to 500 eV). The transmission gain depends on the size of the photon footprint on the sample. Under k-imaging conditions, the energy and momentum resolution are 10.2 meV (FWHM) (4.2 meV with 200 μm slits and Epass = 8 eV) and 0.010 Å-1. The energy filtered X-PEEM mode showed a spatial resolution of 250 nm. As examples, we show 2D band mapping of bilayer graphene, 3D mapping of the Fermi surface of Cu, circular dichroic ARPES for intercalated indenene layers, and the sp valence band of Au. Full-field photoelectron diffraction patterns of Ge show rich structure in k-field diameters of up to 6 Å-1.
Related Concept Videos
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Overview of Electron Microscopy
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Transmission Electron Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.