Related Experiment Video
Updated: Sep 19, 2025

Author Spotlight: Assessing the Impact of Novel Iron Chelators on Cancer Cell Metabolism
Published on: February 23, 2024
Sensitive, selective, and pretreatment-free detection of ferric ions in different solvents based on organic-soluble
Jingfang Shangguan1, Chengjie Qiao1, Yuyang Zhang1
1School of Pharmacy, Xinxiang Medical University Xinxiang Henan 453003 China liuwei@xxmu.edu.cn.
Abstract:
The presence of ferric ion (Fe3+) impurities can reduce the stability and efficiency of organic solvents, which can significantly impact the production of chemicals, food, medical supplies, and daily necessities. Herein we describe the synthesis of organic-soluble carbon dots (CDs) and their first application for Fe3+ detection in various organic solvents without requiring pretreatment procedures. The CA-CDs were prepared via a solvothermal method using caffeic acid (CA) as a precursor and anhydrous ethanol as the solvent. The presence of Fe3+ triggered changes in the fluorescence intensity of CA-CDs and exhibited good linearity in five protonic and non-protonic solvents with different polarities, including ethanol (3.0-50 μM, R 2 = 0.9915), methanol (5.0-50 μM, R 2 = 0.9903), ethyl acetate (5.0-50 μM, R 2 = 0.9945), acetonitrile (6.0-50 μM, R 2 = 0.9998), and dichloromethane (4.0-40 μM, R 2 = 0.9940). The corresponding detection limits were 0.96, 1.66, 1.54, 1.73, and 1.19 μM, respectively. Owing to the formation of an iron hydroxyl complex, CA-CDs demonstrated high selectivity towards Fe3+ over other potentially interfering metal ions in both pure solvents and solvents containing 1% (v/v) water. The accuracy of CA-CDs was validated by comparison with results from the Inductively Coupled Plasma-Optical Emission Spectrometer method. With the above outstanding properties, the proposed CA-CDs were successfully employed for Fe3+ quantification in automotive ethanol gasoline with a detection limit of 2.82 μM. Compared to the contamination and errors associated with sample pretreatment in most conventional assays, the CA-CD-based platform offers low-cost, high sensitivity, selectivity, operational simplicity, and contamination-free detection.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
07:07Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
Published on: March 12, 2015
Related Concept Videos
Precipitation and Co-precipitation
Extraction: Advanced Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...