Quantitative and automatic plan-of-the-day assessment to facilitate adaptive radiotherapy in cervical cancer
Sarah A Mason1,2, Lei Wang1, Sophie E Alexander1,2
1The Institute of Cancer Research, London, United Kingdom.
Abstract:
Objective.To facilitate implementation of plan-of-the-day (POTD) selection for treating locally advanced cervical cancer (LACC), we developed a POTD assessment tool for CBCT-guided radiotherapy (RT). A female pelvis segmentation model (U-Seg3) is combined with a novel quantitative standard operating procedure (qSOP) to identify optimal and acceptable plans.Approach.The planning CT[i], corresponding structure set[ii], and manually contoured CBCTs[iii] (n= 226) from 39 LACC patients treated with POTD (n= 11) or non-adaptive RT (n= 28) were used to develop U-Seg3, an algorithm incorporating deep-learning and deformable image registration techniques to segment the low-risk clinical target volume (LR-CTV), high-risk CTV (HR-CTV), bladder, rectum, and bowel bag. A single-channel input model (iii only, U-Seg1) was also developed. Contoured CBCTs from the POTD patients were (a) reserved for U-Seg3 validation/testing, (b) audited to determine optimal and acceptable plans, and (c) used to empirically derive a qSOP that maximised classification accuracy.Main results.The median (interquartile range) dice similarity coefficient (DSC) between manual and U-Seg3 contours was 0.83 [0.80], 0.78 [0.13], 0.94 [0.05], 0.86 [0.09], and 0.90 [0.05] for the LR-CTV, HR-CTV, bladder, rectum, and bowel. These were significantly higher than U-Seg1 in all structures but bladder. The qSOP classified plans as acceptable if they met target coverage thresholds (LR-CTV⩾99%, HR-CTV⩾99.8%), with lower LR-CTV coverage (⩾95%) sometimes allowed. The acceptable plan minimizing bowel irradiation was considered optimal unless substantial bladder sparing could be achieved. With U-Seg3 embedded in the qSOP, optimal and acceptable plans were identified in 46/60 and 57/60 cases.Significance.U-Seg3 outperforms U-Seg1 and all known CBCT-based segmentation models of the female pelvis both in terms of scope and accuracy (median DSC improvement ranging from 0.03-0.06). The tool combining U-Seg3 and the qSOP identifies optimal plans with equivalent accuracy as two observers. In an implementation strategy whereby this tool serves as the second observer, plan selection confidence and decision-making time could be improved whilst simultaneously reducing the required number of POTD-trained radiographers by 50%.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
05:18Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
Published on: October 6, 2023