Related Experiment Video
Updated: Sep 19, 2025

05:04
Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
1.1K
Development and Testing of a Novel Simulation-Based Mastery Learning Course: Introduction to Extracorporeal Membrane
Charlotte C McEwen1, Iqbal Jaffer1, Elif Bilgic2
1Department of Surgery, Division of Cardiac Surgery, McMaster University, Hamilton, Ontario, Canada.
The Canadian Journal of Cardiology
|June 5, 2025
Abstract
No abstract available in PubMed .
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
1.0K
Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
1.0K
Oxygen Delivering System I: Nasal Cannula and Face Mask
642
The human body requires oxygen to function, and when the natural process of respiration is hindered, external devices, including the following, are needed to help deliver this vital gas.
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
642
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
100
Airway management is essential in emergency and surgical medicine, ensuring ventilation and oxygenation in patients who cannot maintain their own airway. Clinicians use a range of techniques and devices to secure the airway, depending on the patient’s condition and the clinical context. Key methods include endotracheal intubation, rapid sequence intubation (RSI), supraglottic airway devices, and advanced visualization aids. In cases where these approaches fail, surgical airway...
100
Mechanical Ventilation II: Invasive Ventilation
270
Ventilators are essential medical equipment used to aid patients with respiratory difficulties. Their primary function is to assist or replace spontaneous breathing by providing mechanical ventilation. There are two general classes of mechanical ventilators: negative-pressure and positive-pressure ventilators.
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
270
Cardiopulmonary Resuscitation II: ACLS Airway Management
120
Airway management is a key skill in emergency and critical care settings, as maintaining a clear airway is essential for adequate oxygenation and ventilation.Head Tilt-Chin Lift TechniqueThe head tilt-chin lift maneuver is an essential technique primarily used in patients without suspected cervical spine injuries. To perform this maneuver, one hand is placed on the patient’s forehead, and gentle pressure is applied backward to tilt the head. The fingertips of the other hand are positioned...
120