Underwater Gas Chromatograph-Quadrupole Mass Spectrometer for In Situ Analysis of VOCs in Deep Sea
Shihao Lu1,2, Kun Ding1, Qixin Liu1
1Department of Instrumentation & Analytical Chemistry, Key Laboratory of Deep-sea Composition Detection Technology of Liaoning Province, Dalian Institute of Chemical Physics, CAS, 457 Zhongshan Road, Dalian 116023, China.
None:
An underwater gas chromatograph-quadrupole mass spectrometer (UGC-qMS) for in situ qualitative and quantitative analysis of volatile organic compounds (VOCs) in the deep sea was developed and evaluated. The UGC-qMS utilizes a membrane inlet, enrichment-thermal desorption, capillary column separation, and EI-quadrupole mass spectrometer detection. The overall dimension of the UGC-qMS is Φ220 mm × 960 mm, 100 kg in air, 58 kg in water, and the design maximum working depth is 6000 m. The UGC-qMS is powered by external power supply with average power consumption ≤ 100 W. The gas consumption is approximately 1 mL/min, supporting over 500 h of underwater operation in a single deployment. Limits of detection for ethane, propane, n-butane, benzene, toluene, and p-xylene under one enrichment process are 0.050, 0.041, 0.028, 0.20, 0.28, and 0.37 μg/L in water, respectively. The linearity of response is approximately 2 orders of magnitude. The UGC-qMS was tested at a depth of 4500 m in the South China Sea to validate its underwater feasibility. This work marks the first successful deployment of GC-MS for in situ analysis in deep sea. Covering a broad boiling point range from ethane to naphthalene, the UGC-qMS surpasses existing underwater in situ analytical devices in VOCs analysis, offering a powerful tool for deep-sea chemical exploration.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...