Related Experiment Video
Updated: Jan 18, 2026

An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
Frequency handling by reinforcement of predictive 2DoF-MPC and state observer LADRC for smart power system
1Department of Control & Instrumentation Engineering, Center for Sustainable Energy Systems, Center for Smart Mobility and Logistics, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia.
Abstract:
The preservation of stability is essential for the efficient and reliable functioning of the electrical transmission system. Frequency oscillations are prevalent in interconnected power systems (IPS) and may lead to instability; therefore, it is crucial to monitor and examine them meticulously. Effective frequency management is essential for regulating frequency output in an interconnected smart power system (ISPS) that includes renewable energy sources (RESs), redox flow batteries (RFBs) and static synchronous series compensators (SSSCs). In view of the challenge presented, this research introduces an efficient control architecture that utilizes a 2 degree of freedom-based model predictive controller (2DoF-MPC) to enhance system performance. Additionally, it integrates a linear active disturbance rejection control (LADRC) to employ a state observer alongside the evolving frequency management. The convergence of the predictive and state observer frameworks results in a robust 2DoF-MPC-LADRC to manage frequency disturbances and uncertainties in the power system. The suggested technique is thoroughly validated across several parameters for ISPS, instilling confidence in its capacity to attain minimal frequency variation in multiple scenarios. The performance of the proposed controller design shows that the frequency performance in area 1 and area 2 settles in 5.085 sec and 3.965 sec, when the load changes by 3 %, and it settles in 4.655 sec and 4.050 sec, respectively, when the load changes by 5 %.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
State Space Representation
Consider an RLC circuit, a...
Load-frequency control
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Fast Decoupled and DC Powerflow
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...