Related Experiment Video
Updated: Aug 17, 2026

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
Lattice Distortion Promoting Wavelength-Tunable Emissions in Cu(I)-Based Halides for Thermography and
Kai Han1,2, Shuai Zhang1, Jiance Jin2
1State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Fiber Laser Materials and Applied Techniques, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, 510641, China.
Abstract:
Low dimensional hybrid metal halides as a chemically tunable platform achieve multi-functional optical applications with versatile luminescence mechanisms. Herein, we design and prepare Cu(I)-based hybrid halide (DMAP)Cu3I4 (DMAP = 4-Dimethylaminopyridine), with ambient temperature-induced photoluminescence evolution from red to near-infrared emissions. The in situ variable-temperature crystallographic study reveals lattice distortion with more disordered [Cu3nI4n]n- units appear at high temperature, further indicating that the observed wavelength-tunable emission is attributed to transitions from Cu cluster center to halogen-to-metal charge transfer. Thus, (DMAP)Cu3I4 shows a compelling thermometric precision (high sensitivities of 0.0001-0.6 K-1) at a wide temperature range of 80-300 K. In particular, the remote thermography is established with a high spatial resolution of -20 lp mm-1 by processable thin films. These findings enhance the potential for molecular-level illumination in Cu(I)-based halides and contribute to the exploration of their optoelectronic properties.
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...
Bioreactor Controls-I

