Diffusion-based image translation model from low-dose chest CT to calcium scoring CT with random point sampling
Ji-Hoon Jung1, Jong Eun Lee2, Hyun Seo Lee3
1Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul, South Korea; Department of Biomedical Engineering, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
Background:
Coronary artery calcium (CAC) scoring is an important method for cardiovascular risk assessment. While artificial intelligence (AI) has been applied to automate CAC scoring in calcium scoring computed tomography (CSCT), its application to low-dose computed tomography (LDCT) scans, typically used for lung cancer screening, remains challenging due to the lower image quality and higher noise levels of LDCT.
Purpose:
This study presents a diffusion model-based method for converting LDCT to CSCT images with the aim of improving CAC scoring accuracy from LDCT scans.
Methods:
A conditional diffusion model was developed to generate CSCT images from LDCT by modifying the denoising diffusion implicit model (DDIM) sampling process. Two main modifications were introduced: (1) random pointing, a novel sampling technique that enhances the trajectory guidance methodology of DDIM using stochastic Gaussian noise to optimize domain adaptation, and (2) intermediate sampling, an advanced methodology that strategically injects minimal noise into LDCT images prior to sampling to maximize structural preservation. The model was trained on LDCT and CSCT images obtained from the same patients but acquired separately at different time points and patient positions, and validated on 37 test cases.
Results:
The proposed method showed superior performance compared to widely used image-to-image models (CycleGAN, CUT, DCLGAN, NEGCUT) across several evaluation metrics, including peak signal-to-noise ratio (39.93 ± 0.44), Local Normalized Cross-Correlation (0.97 ± 0.01), structural similarity index (0.97 ± 0.01), and Dice similarity coefficient (0.73 ± 0.10). The modifications to the sampling process reduced the number of iterations from 1000 to 10 while maintaining image quality. Volumetric analysis indicated a stronger correlation between the calcium volumes in the enhanced CSCT images and expert-verified annotations, as compared to the original LDCT images.
Conclusions:
The proposed method effectively transforms LDCT images to CSCT images while preserving anatomical structures and calcium deposits. The reduction in sampling time and the improved preservation of calcium structures suggest that the method could be applicable for clinical use in cardiovascular risk assessment.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT