Dataset for tilt-up solid and composite insulated wall panels under combined axial and lateral loading

Salam Al-Rubaye1, Marc Maguire1

  • 1Durham School of Architectural Engineering and Construction, University of Nebraska-Lincoln, 1110 S. 67th St., Omaha, NE 68182, United States.

Data in Brief
|June 9, 2025
PubMed
Summary

This study evaluated concrete insulated wall panels (CIPs) and traditional tilt-up panels, assessing connector performance and structural behavior. The findings offer valuable data for engineers and researchers on insulated wall systems.

Related Concept Videos

Posttensioned Masonry Walls01:15

Posttensioned Masonry Walls


Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
129
Masonry Loadbearing Walls01:16

Masonry Loadbearing Walls

Masonry load-bearing walls, constructed from materials like brick, stone, or concrete masonry units, serve as a crucial component in building structures by supporting the loads from floors and roofs and transferring them to the foundation. These walls, known for their compressive strength, can be reinforced or unreinforced to suit different building needs, accommodating both the dead and live loads while maintaining safety through lower working stresses compared to the materials' ultimate...
102
Composite Masonry Walls01:18

Composite Masonry Walls

Composite masonry walls combine multiple wythes of the same or different masonry materials to create a unified structure. These walls feature wythes that are bonded together either through mortar-filled collar joints, grouted spaces, or more commonly, with rigid metal ties and reinforcements, with the use of masonry header units being rare. Metal ties are preferred because they effectively minimize water penetration, as these walls primarily absorb moisture and then release it into the...
1.1K
Unsymmetric Loading of Thin-Walled Members01:23

Unsymmetric Loading of Thin-Walled Members

Thin-walled members with non-symmetrical cross-sections are vital to engineering structures, offering material efficiency and structural integrity. However, unsymmetrical loading on these members leads to complex stress distributions, resulting in simultaneous bending and twisting can cause deformation or structural failure. The interaction between bending and twisting requires detailed analysis to ensure structural resilience.
The concept of the shear center is crucial in countering the...
101
Eccentric Axial Loading in a Plane of Symmetry01:16

Eccentric Axial Loading in a Plane of Symmetry

Eccentric axial loading occurs when an axial load is applied away from the centroidal axis of a structural member. This scenario is common in engineering, where structural elements may not be directly aligned due to various design or functional requirements.
165
Masonry Curtain Walls01:20

Masonry Curtain Walls

Masonry curtain walls employ brick or stone veneers supported by the building's structure to form an external cladding system that is both aesthetically appealing and functional. These walls are erected through two principal techniques, first by traditional layering of masonry units and second by using prefabricated panels. Traditional construction relies on steel shelf angles attached to the spandrel beam for support, with high-bond mortars ensuring secure attachment of masonry veneer...
1.0K