Related Experiment Video
Updated: Sep 22, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Effect of respiratory apparatus on timing and depth of breathing in man
Abstract:
The effects on breathing of (1) nose-clips, with and without mouthpieces, (2) tube breathing with incremental dead spaces up to 600 ml, and (3) a Venturi mask with a high air inflow reducing the effective dead space to zero were measured with respiratory inductance plethysmography. The effective dead spaces of the lengths of tubing were 25% smaller than their water-displacement volumes. The principal response to the increase in dead space was an increase in VT without any change in frequency or timing. The increase in VE was 16% greater than the ventilation of the effective dead space. The facemask with a high flow of air did not affect the pattern of breathing. External devices alone (nose-clips, mouthpieces) by themselves brought about a significant increase in VT (+10%, P less than 0.05) and a small drop in frequency, which in the case of a nose-clip alone was large enough to be significant (-15%, P less than 0.05). The increase in DS with the change from nasal to oral breathing may have contributed to the accompanying increase in VT; the fall in frequency with the nose-clip alone might have been caused by stimulation of receptors in the trigeminal area.
More Related Videos
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
06:26Custom Smartphone Application to Guide Locomotor-Respiratory Coupling in the Field Using Step-Adaptive Breathing Sounds
Published on: September 27, 2024
Related Concept Videos
Factors Affecting Respiration
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities I
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...