Related Experiment Video
Updated: Aug 12, 2026

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
Several Probes Derived from Tetraphenyl Ethene and Triphenylamine for Cu(II) and Intracellular Carbon Monoxide
Yulang Fei1,2,3, Ou Zhang2,4, Kai Sun5
1Department of Biomedical Research Center, Medical College, Xijing University, Xi'an 710123, Shaanxi Province, China.
Abstract:
Optical detection is a promising method for Cu2+ detection with merits, including short sensing times, low cost, sensitive response, and ease of implementation. In this work, tetraphenylethene and triphenylamine were selected as the structural cores for constructing optical probes for Cu2+. The tetraphenylethene and triphenylamine groups were bonded to a N-N group, forming a probe structure. Additionally, there were two -OH groups near the N-N group, offering additional recognition sites to improve the sensing selectivity. The discussion covered the geometry, electronic transitions, optophysical properties, and spectroscopic behaviors toward copper-(II). It was concluded that the -OH group improved the sensing selectivity by increasing the affinity between the probe and Cu2+. The electron donors in these dyes compromised the sensing selectivity but decreased the emission recovery time. The optimal probe (P1) decreased its emission quantum from 7.8 to 0.2% by Cu2+ and then recovered to 7.4% by CO within 529 s, with its emission spectrum well recovered. The emission recovery of P1 was sensitive to temperature, and a high temperature (40 °C) helped P1 emission recovery. The recognition principle was yielding a nonemissive adduct between the probe and Cu2+ with a complexation constant of 6.25 × 107 L/mol. The sensing mechanism toward Cu2+ was revealed as the combination of static and dynamic sensing with Job's plot, lifetime comparison, 1H NMR, and IR comparison. The other four probes, having no -OH groups, exhibited poor sensing selectivity and lower emission recovery values. Their emission recovery times were shorter than that of P1 due to the steric factor and electronic structure. The practical sensing and imaging performance of P1 was tested.
More Related Videos
07:07Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
Published on: March 12, 2015
11:38Quantifying the Binding Interactions Between CuII and Peptide Residues in the Presence and Absence of Chromophores
Published on: April 5, 2022