Jenny L Zheng1, Leta J Ashebo1, J Todd R Lawrence1
1Division of Orthopaedics, The Children's Hospital of Philadelphia, Philadelphia, PA, USA.
Abstract:
Introduction: Cast saws may cause burns secondary to generated heat. This study aimed to develop a real-time temperature feedback system to alert users of increasingly unsafe saw blade temperatures. Methods: A sensor device was designed for the Stryker 940 cast saw, measuring temperature at the two blade ends and providing real-time feedback through an LED-light system (green, yellow, red, blinking red) with adjustable temperature ranges. LED ranges were determined using temperature data from four cast technicians. "Skin" touches were assessed with conductivity from the blade to copper strips within cast padding. Users were asked to remove standardized casts, completing three test runs with LED indicators off and three with the light on. Time spent within each temperature range and number of "skin" touches per run were analyzed. Results: With the LED on, the percentage of time spent in the green zone increased (p < .0001) while percentage of time in the red zone decreased (p < .0001) across all test groups. Average time per run increased with the LED on. Although not statistically significant, the number of "skin" touches decreased across all groups with LED on (p = .0630). Conclusions: A temperature-sensitive LED light connection to cast saw blades can potentially decrease user time spent in unsafe temperatures and risk of cast saw burns.
More Related Videos
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
06:43Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...