Related Experiment Video
Updated: Jun 12, 2025

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Inter-Night Variability of Nocturnal Pulse Oximetry in People Living With Motor Neuron Disease: A Retrospective
Steven Luu1, Olivia McGuiness2,3, Collette Menadue3
1Sleep and Circadian Group, Woolcock Institute of Medical Research, Macquarie University, Macquarie Park, Australia.
Background And Objective:
Nocturnal pulse oximetry (NPO) is a simple and inexpensive assessment tool that has previously been shown to correlate with prognosis and timing of non-invasive ventilation (NIV) initiation in people living with motor neuron disease (plwMND). However, the optimal number of nights for measuring NPO has not been defined for this population, with other respiratory conditions exhibiting both low and high night-to-night variability in NPO parameters. This study aims to determine the inter-night variability in NPO data over three nights in plwMND.
Methods:
We conducted a retrospective analysis of 132 studies in which plwMND underwent three consecutive nights of NPO. Intraclass correlation coefficients (ICC) were used to assess the reliability of key NPO parameters, including mean percentage of total recording time with oxygen saturation (SpO2) < 90% (T90), oxygen desaturation index (ODI), basal SpO2 and nadir SpO2. The proportion of plwMND meeting NIV criteria based on single-night versus multi-night assessments was also compared.
Results:
Excellent reliability was observed for T90 (ICC(1) = 0.940) and ODI (ICC(1) = 0.901), while basal SpO2 (ICC(1) = 0.845) and nadir SpO2 (ICC(1) = 0.768) demonstrated good reliability. However, relying on a single-night NPO assessment failed to identify 12% of plwMND who met NIV criteria when evaluated over three nights.
Conclusion:
Despite good to excellent inter-night variability of NPO data in plwMND, multi-night NPO monitoring improves the accuracy of identifying plwMND requiring NIV. These findings support the need for multi-night assessments to enhance clinical decision-making in MND management.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation