Effect of Warmer Height (Standard versus Custom) on Neonatal Chest Compression Performance: A Cross-Over Simulation
Tamara Alexander1, Lise DeShea1, Leonard W Wilson2
1Neonatal-Perinatal Medicine, Department of Pediatrics, University of Oklahoma Health, Oklahoma City, Oklahoma.
None:
This study aimed to evaluate whether a custom warmer height improves the quality and consistency of chest compressions (CCs) compared with a standard warmer height during simulated neonatal resuscitation.Cross-over study using simulated neonatal resuscitation. A controlled research environment equipped with a 12-camera motion capture system, four in-floor multi-axis force plates, a neonatal manikin, and resuscitation equipment. Biomechanical assessments were recorded every 2 minutes during a 20-minute simulation for each condition. Twenty Neonatal Resuscitation Program (NRP)-trained providers. Each participant performed two 20-minute CC sessions-one with the warmer at the standard 100 cm height and one at a custom height selected by the participant. CC depth, force, and rate; participant back angle, heart rate, and self-reported exertion, were analyzed at 2-minute intervals.Compared with the standard height, the custom height resulted in greater and more consistent CC depth and force while maintaining compression rate. Participants also exhibited a greater back angle, and lower heart rate, and reported reduced exertion under the custom height condition.Allowing NRP-trained providers to adjust warmer heights led to improved CC quality and consistency, suggesting that customizable warmer heights may enhance neonatal resuscitation performance. KEY POINTS: · Custom warmer height chosen by NRP-trained providers resulted in more consistent and greater CC depth and force.. · It also was associated with less provider fatigue, compared with standard height.. · During neonatal resuscitation, frontline healthcare professionals changed.. · Participant heart rate was lower when using the custom versus standard height.. · Our findings support the need for guidelines on adjusting warmer height during neonatal cardiopulmonary resuscitation..
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...