Effectiveness of the hypotension prediction index in non-cardiac surgeries: a systematic review, meta-analysis and
Vitor Alves Felippe1, Ana C Pinho1, Lucas M Barbosa2
1Instituto Nacional de Câncer (INCA), Rio de Janeiro, RJ, Brazil.
Background:
The efficacy of the Hypotension Prediction Index (HPI) for reducing Intraoperative Hypotension (IOH) among patients undergoing non-cardiac surgeries remains unclear. We aimed to perform a systematic review, meta-analysis, and trial sequential analysis to determine whether the HPI is effective for adult patients undergoing non-cardiac surgeries. This study was prospectively registered in the PROSPERO database (CRD42024571931).
Methods:
PubMed, Embase, and Cochrane were systematically searched for Randomized Controlled Trials (RCTs) comparing HPI-guided therapy with standard care in non-cardiac surgeries. We computed Mean Difference (MD) and Risk Ratios (RR) for continuous and binary outcomes, respectively, with 95 % Confidence Intervals (95 % CI). Statistical analyses were performed using R Software, version 4.2.3.
Results:
We included 11 RCTs, comprising a total of 789 patients, of whom 395 (50.1 %) received HPI-guided management. HPI significantly reduced the Time-Weighted Average (TWA) of Mean Arterial Pressure (MAP) < 65 mmHg (MD = -0.23 mmHg.min-1; 95 % CI -0.35 to -0.10; p < 0.01) and the Area Under the Curve (AUC) of MAP < 65 mmHg (MD = -97.2 mmHg.min-1; 95 % CI -143.4 to -50.98; p < 0.01). HPI also decreased the duration of MAP < 65 mmHg (MD = -16.22 min; 95 % CI -25.87 to -6.57; p < 0.01) and the number of hypotensive episodes per patient (MD = -3.38; 95 % CI -5.38 to -1.37; p < 0.01). No significant differences were observed in the number of hypotensive events, phenylephrine use, or AKI incidence (p > 0.05).
Conclusion:
In adult patients undergoing non-cardiac surgeries, HPI use was associated with a reduction in the duration and severity of IOH, with no significant difference for adverse events. Limitations include significant heterogeneity across studies, differences in HPI implementation, and lack of long-term outcome data.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure