Related Experiment Video
Updated: Jul 13, 2026

A Simplified Technique for In situ Excision of Cornea and Evisceration of Retinal Tissue from Human Ocular Globe
Published on: June 12, 2012
Handshake technique for removal of fluocinolone acetonide implant from the vitreous cavity
Raja Rami Reddy1,2, Vanita Pathak Ray3, Deependra Vikram Singh4,5
1Retina, Ophthalmology, Neoretina Eyecare Institute, Hyderabad, Telangana, India.
Abstract:
We describe a simple technique for removing fluocinolone acetonide (FAc) implant using 25 G instrumentation in an eye with uncontrolled glaucoma. The technique involved freeing the implant from the pars plana, lifting it from the posterior pole with 25G+Grieshaber Maxgrip forceps and transferring it to another forceps. The implant was then realigned coaxially and successfully removed through a 25G cannula without getting it dislodged. Fluocinolone implant could be safely removed through 25 G cannula in toto, and removal resulted in good control of intraocular pressure at 3-month and 9-month follow-up. This innovative bimanual handshake technique to transfer and realign the implant coaxially is a quicker and safer way to remove FAc implant, which avoids removing the cannula and thereby retains all advantages of 25G cannula, including better sclerotomy closure.
More Related Videos
07:13An Alternative and Validated Injection Method for Accessing the Subretinal Space via a Transcleral Posterior Approach
Published on: December 7, 2016
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023