Related Experiment Video
Updated: Jun 16, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Wearable device for axillary lymph node screening in breast cancer based on infrared thermography and artificial
Xiaoying Zhong1,2, Jinqiu Deng3, Ping Lu1
1Department of Breast Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, No. 3 Dongdan, Dongcheng District, Beijing, China.
Background:
Breast cancer (BC) is the most prevalent cancer among women worldwide, and patients with metastasis to axillary lymph nodes (ALN) experience significantly lower survival rates. Current imaging-based screening methods often suffer from low sensitivity and limited accessibility for detecting ALN metastasis in breast cancer patients. In this study, we present an AI-based infrared thermography system for ALN metastasis detection to improve diagnostic accessibility and reduce intervention-related morbidity.
Methods:
In this study, we curated an internal and external cohort for developing and accessing the deep learning model-based infrared thermography system. The internal cohort included 460 inpatient participants from Peking Union Medical College Hospital, randomly divided into a training set (70%) for model development and a hold-out internal validation set (30%) for initially model evaluation. The external cohort, consisting of 80 patients from both outpatient and inpatient departments recruited from Longfu Hospital, served for independent validation of the developed screening tool.
Results:
The developed model AI-IRT for axillary lymph node (ALN) metastasis detection exhibited high diagnostic performance, achieving an Area Under the Curve (AUC) of 0.9424 and an accuracy of 0.8478 in the internal validation set, with a sensitivity of 0.8958 and specificity of 0.8222. In a tertiary classification scenario, the model produced an AUC of 0.8936, with corresponding accuracy, sensitivity, and specificity values of 0.7246, 0.7246, and 0.7852, respectively. In the external validation set, the AI-IRT system achieved an AUC of 0.881 and an accuracy of 0.875, with a sensitivity of 0.892 and specificity of 0.861. For the tertiary classification, the model attained an AUC of 0.771 and an accuracy of 0.613, with both sensitivity and specificity at 0.613 and 0.695, respectively.
Conclusion:
Evaluated on both curated internal and external cohorts, the proposed AI-IRT demonstrated strong performance across multiple centers, highlighting its potential to enhance pre-operative and intra-operative decision-making in the treatment of breast cancer patients.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...