Optimizing Attenuation Correction in 68Ga-PSMA PET Imaging Using Deep Learning and Artifact-Free Dataset Refinement.
Masoumeh Dorri Giv1, Guluzar Ozbolat2, Hossein Arabi3
1Nuclear Medicine Research Center, Department of Nuclear Medicine, Ghaem Hospital, Mashhad University of Medical Science, Mashhad 6541747187, Iran.
This study introduces a new method to clean corrupted PET-CT images, improving deep learning for 68Ga-PSMA PET imaging accuracy by removing artifacts without needing extra scans.
Area of Science:
- Medical Imaging
- Artificial Intelligence in Healthcare
- Nuclear Medicine
Background:
- Quantitative accuracy in Positron Emission Tomography (PET) imaging relies on accurate attenuation correction (AC).
- Artifacts in CT-based AC (CT-AC) for 68Gallium-Prostate-Specific Membrane Antigen (68Ga-PSMA) PET, including motion and truncation, degrade image quality.
- These artifacts hinder the training of deep learning (DL)-based AC models.
Purpose of the Study:
- To develop and validate a novel artifact-refinement framework for PET-CT image datasets.
- To enable the training of an image-domain deep learning AC model using a purified dataset, eliminating the need for anatomical reference scans.
- To enhance the quantitative accuracy and robustness of 68Ga-PSMA PET imaging.
Main Methods:
- A residual neural network (ResNet) was trained on 828 whole-body 68Ga-PSMA PET-CT scans.
- Artifact-affected images were identified and excluded using voxel-level error metrics.
- The model was retrained on the refined dataset using an L2 loss function for improved performance.
Main Results:
- The model trained on the purified dataset showed significantly improved performance metrics (e.g., ME = -0.009 ± 0.43 SUV, MAE = 0.09 ± 0.41 SUV, SSIM = 0.96 ± 0.03).
- Enhanced quantitative accuracy and robustness were observed during internal and external validation compared to a model trained on unfiltered data.
- The artifact-refinement framework effectively mitigated errors caused by corrupted images.
Conclusions:
- The proposed data purification framework substantially improves deep learning-based AC for 68Ga-PSMA PET.
- This method enhances image fidelity and clinical applicability by enabling reliable PET imaging without anatomical references.
- The framework addresses critical challenges in artifact reduction for quantitative PET analysis.