Related Experiment Video
Updated: Jun 16, 2025

The Role of Fabric in Frictional Properties of Phyllosilicate-Rich Tectonic Faults
Published on: November 6, 2021
Active Fault Dislocation-Induced Mechanical Response of Polyurethane-Solidified Track in Tunnels
Wei Chen1, Dan Wu1, Minzhe Yu1
1School of Civil Engineering, Central South University, Changsha 410075, China.
None:
The dislocation of the active fault zone altered the stress distribution and geometry of the track structure in the tunnel, which in turn affected the safety and stability of the train operation. Polyurethane-solidified track bed (PSTB) is suitable for sections crossing through active fault zones due to its excellent serviceability and adaptability to deformation. In this study, the stress and deformation response induced by active fault dislocation are investigated for this novel track structure. The corresponding deformation of track structure is subsequently introduced into a vehicle-track dynamics model to calculate the train operation safety index. The study examines the impact of fault displacement on railway track structures, revealing significant vertical deformation in rails that corresponds to the displacement magnitude. The effects are mainly confined to the active fault zone and its immediate surroundings, with variations depending on the fault zone's structural characteristics. Key factors such as larger displacements, steeper fault angles, and narrower fault zones increase stress on track components, particularly the wide sleeper, which is prone to cracking and represents a structural vulnerability. Higher fault displacement, narrower zones, steeper angles, and increased train speeds elevate derailment risks and wheel load reduction rates, potentially exceeding safety limits. To ensure safety under typical fault conditions, train speeds should not exceed 250 km/h for PSTB with a 40 mm displacement and a 60° fault angle. These findings provide critical guidance for railway construction in fault-prone areas.
More Related Videos
06:55Kinematic History of a Salient-recess Junction Explored through a Combined Approach of Field Data and Analog Sandbox Modeling
Published on: August 5, 2016
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Circular Shafts - Elastoplastic Materials
As torque on the...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Elasticity in Concrete
Plastic Behavior
Tension Response at Adherens Junctions
α-Catenin as a Mechanosensory Protein
The α-catenin of adherens junctions is an allosteric protein with three VH (vinculin...
Rolling Resistance
For instance, imagine a hard cylinder rolling on a comparatively soft surface. The cylinder's weight compresses the surface beneath it. As the cylinder moves, the material in front of it slows down...