Optimization of time and frequency allocations in a TFDMA PON with diverse user conditions and diversified rate

Optics Letters
|June 13, 2025
PubMed

Related Concept Videos

Properties of Fourier Transform II01:24

Properties of Fourier Transform II

The Fourier Transform (FT) is an essential mathematical tool in signal processing, transforming a time-domain signal into its frequency-domain representation. This transformation elucidates the relationship between time and frequency domains through several properties, each revealing unique aspects of signal behavior.
The Frequency Shifting property of Fourier Transforms highlights that a shift in the frequency domain corresponds to a phase shift in the time domain. Mathematically, if x(t) has...
185
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
80
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
98
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
113
Design Example01:23

Design Example

The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
321
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
85