Related Experiment Video
Updated: Jun 16, 2025

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Significant enhancment of the accuracy of impurity determination in vacuums using classification one-point
Abstract:
Laser-induced breakdown spectroscopy (LIBS) is a highly promising technique for the in-situ, real-time diagnosis of impurity deposits on the inner walls of tokamak devices. The deposited impurity on plasma-facing materials (PFCs) pose a significant risk to the steady-state operation of the tokamak. Under vacuum conditions, an accurate quantitative analysis of the thin co-deposition layers is a technical challenge. In this study, 30 co-deposited layer samples of tungsten (10.0-92.3 a.t.%), molybdenum (2.0-77.8 a.t.%), iron (2.9-12.1 a.t.%) and copper (1.2-18.7 a.t.%) were prepared to simulate the co-deposition layers found on PFCs in Experimental Advanced Superconducting Tokamak (EAST). A variation of the CF-LIBS algorithm, the so-called One Point Calibrated LIBS (OPC-LIBS), was employed to analyze these co-deposited layer samples under conditions of 5 × 10-5 mbar. It was found that the matrix matching degree among the measured samples and the selection of standard samples play a decisive role in the quantitative analysis capability of OPC-LIBS. In actual situations, the composition of the co-deposited impurity layers at different locations in the Tokamak will be quite different. We addressed this challenge by developing the Classified OPC-LIBS (COPC-LIBS) model, an enhanced version of OPC-LIBS with pre-classification to offset matrix effects in LIBS analysis. For tungsten in the co-deposition layers, the root mean square (RMSE) calculated by the CF-LIBS method was 14.7, the OPC-LIBS method was 11.5, and the newly invented COPC-LIBS was reduced to only 5.1. The COPC-LIBS method is a highly efficient technique that can precisely measure the distribution of co-deposited layers on the surface of inner wall materials. The diagnostic data obtained from this method will provide valuable insights into the interaction between plasma and wall materials during the operation of fusion devices.
More Related Videos
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
10:17Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...