Related Experiment Video
Updated: Jun 16, 2025

Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Contrast-enhanced mammography for breast cancer detection and diagnosis with high concentration iodinated contrast
Federica Pediconi1, Annarita Speranza2, Giuliana Moffa1
1Department of Radiological, Oncological and Pathological Sciences, Sapienza, University of Rome, Policlinico "Umberto I", Rome, Italy.
Objectives:
We assessed the diagnostic performance of contrast-enhanced mammography (CEM) using a high-concentration iodinated contrast medium (HCCM, 400 mgI/mL) to determine whether the reduced iodine dose and increased iodine delivery rate (IDR) achieved might offer a more sustainable alternative to CEM performed with lower iodine concentrations.
Methods:
This two-center retrospective study included 205 patients who underwent CEM between March 2021 and February 2022. Patients were injected with HCCM at 1.0 mL/kg bodyweight at an IDR of 1.2 gL/s. Standard cranio-caudal and mediolateral-oblique views were acquired. Images were reviewed independently by two experienced radiologists who were blinded to patient clinical and imaging information. Diagnostic performance, including sensitivity, specificity, and accuracy, was assessed based on histological or long-term imaging follow-up as the reference standard.
Results:
Among the 205 patients, 149 (72.7%) had malignant lesions, and 56 (27.3%) had benign findings. The sensitivity and specificity of CEM were 96-97% and 84-87.5%, respectively, with an overall accuracy of 93-95%. The IDR achieved with HCCM resulted in excellent contrast enhancement, particularly in patients with aggressive malignancies. ROC analysis confirmed the good diagnostic performance, with AUC values of 0.90-0.92. Compared to conventional mammography and ultrasound, CEM demonstrated significantly higher diagnostic accuracy, especially in patients with dense breast tissue.
Conclusions:
CEM with HCCM provides excellent diagnostic performance, achieving high sensitivity and specificity while allowing for a reduced iodine dose and increased IDR. This approach may offer a more sustainable alternative to conventional contrast media without compromising diagnostic accuracy, particularly for the detection and characterization of aggressive breast lesions.
Critical Relevance Statement:
This study demonstrates that reducing the volume of injected contrast media while increasing iodine concentration maintains the diagnostic benefits of CEM, further supporting its potential to improve early cancer detection, thereby advancing clinical radiology practices and optimizing screening strategies for women with dense breasts.
Key Points:
Currently, CEM protocols utilize a variety of iodine concentrations and flow rates. CEM with high-concentration contrast (400 mgI/mL) achieved 96% sensitivity and 87.5% specificity. High-concentration contrast in CEM improves early detection of aggressive breast cancers.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
13:43Intraductal Delivery and X-ray Visualization of Ethanol-Based Ablative Solution for Prevention and Local Treatment of Breast Cancer in Mouse Models
Published on: April 1, 2022
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...