Related Experiment Video
Updated: May 12, 2026

Asymmetric Walkway: A Novel Behavioral Assay for Studying Asymmetric Locomotion
Published on: January 15, 2016
Instrument-supported gait analysis characterizes gait domain changes in patients with suspected normal pressure
Carolin Semmler1,2, Veronika Wunderle3,4, Taylan D Kuzu5,6
1Faculty of Medicine, University of Cologne, Cologne, Germany. carolin.semmler@uk-koeln.de.
Background:
Idiopathic Normal Pressure Hydrocephalus (iNPH) is a potentially reversible cause of cognitive impairment, urinary incontinence, and gait disturbances, which typically present with a characteristic slow, shuffling, and wide-based gait. Gait velocity, which is reduced relative to healthy controls, improves in iNPH patients following a spinal tap test. This study aimed at evaluating the criterion of a 20% gait velocity improvement in the 10 m walk test to identify responders and non-responders in a cohort of patients with probable iNPH receiving a spinal tap test as well as the added value of instrument-supported gait analysis.
Methods:
We assessed pace, rhythm, variability, postural control, and force in 59 patients with clinically suspected iNPH undergoing a spinal tap test, applying the 10 m walk test and an instrument-supported gait analysis. The change in gait velocity assessed in the 10 m walk test was used to differentiate patients with a positive response to the spinal tap (> 20% improvement, responders) from those with no relevant response (< 20% improvement, non-responders). Group differences were analyzed using chi-square tests, independent sample t-tests, Mann-Whitney-U tests and repeated measure ANOVAs.
Results:
Unlike non-responders (n = 39), responders (n = 20) showed significant changes in the gait domain pace in the 10 m walk test. Moreover, instrument-supported gait analyses revealed additional improvements in the gait domains variability, rhythm, postural control and force in responders only.
Interpretation:
This study confirmed the clinical utility of the 20% gait velocity improvement criterion for differentiating responders and non-responders in a cohort of patients with mostly probable iNPH, in whom clinical parameters alone were insufficient for classification. Notably, instrument-supported gait analysis validated this criterion by providing a more comprehensive characterization of gait disturbances compared to the 10 m walk test. However, further-especially longitudinal-studies are needed to reveal the full potential of the instrument-supported gait analysis in patients with (early/probable) iNPH.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure

