Related Experiment Video
Updated: Jun 16, 2026

Design, Fabrication, and Experimental Characterization of Plasmonic Photoconductive Terahertz Emitters
Published on: July 8, 2013
Benchmarking TERS and TEPL probes: towards a reference sample for quantification of near-field enhancement factors in
James Kerfoot1, Elizabeth J Legge2, Amy Collins3
1Nanoscale and Microscale Research Centre (nmRC), University of Nottingham, University Park, Nottingham, NG7 2RD, UK. james.kerfoot3@nottingham.ac.uk.
Abstract:
Benchmarking the near-field signal enhancement attained using plasmonic metal-coated atomic force microscopy (AFM) probes for tip-enhanced Raman spectroscopy (TERS) and tip-enhanced photoluminescence (TEPL) measurements is challenging given the absence of a suitable reference sample that is simple to prepare, easy to use and compatible with different instrument configurations. To this end, in this study, we have fabricated a flake of monolayer tungsten diselenide (1L-WSe2) stamped across the interface of gold and silver thin films on silicon dioxide and glass. We have demonstrated these samples to be effective for the facile determination of near-field Raman and photoluminescence contrast factors in both gap and non-gap mode, respectively. We show that the near-degenerate E12g + A1g and 2LA(M) peaks in the Raman spectra of WSe2 enable quantification of Raman contrast factors, with a ∼1.6-fold increase in TERS signal enhancement in gap mode, relative to non-gap mode, observed for a typical probe. Similar differences in the photoluminescence contrast factors were observed comparing in-contact and out-of-contact signal intensity ratios from gap and non-gap mode TEPL measurements. Moreover, in developing a reference methodology we found that the line shape of the TEPL profile was dependent upon the magnitude of the signal enhancement, with a disproportionate increase in the longer wavelength shoulder of the emission observed in gap mode. As this contribution to the asymmetric line shape is tentatively assigned to a dark exciton, which possesses an out-of-plane transition dipole moment, our TEPL measurements indicate that the directionality of the near-field enhancement provides a further handle enabling quantification of probe performance. Using samples prepared on glass, and comparing results obtained from two different instruments, each with a different excitation laser wavelength and optical access, we demonstrate the universal applicability of our reference material for sensitivity benchmarking of metallised AFM probes in both gap and non-gap mode, suitable for both reflection and transmission geometries, and across the range of laser wavelengths typically used for TERS and TEPL.
More Related Videos
10:35Using Microwave and Macroscopic Samples of Dielectric Solids to Study the Photonic Properties of Disordered Photonic Bandgap Materials
Published on: September 26, 2014
07:43A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency
Published on: October 5, 2019
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Tandem Mass Spectrometry
Distance Measurements by Taping
Distance Corrections
Electronic Distance Measuring Instruments
Design Example: Measuring Distance Between Two Points with Obstructions