Related Experiment Video
Updated: Sep 19, 2025

Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Replacing Attention With Modality-Wise Convolution for Energy-Efficient PPG-Based Heart Rate Estimation Using
Abstract:
Continuous monitoring of Hearth Rate (HR) based on photoplethysmography (PPG) sensors is an essential capability of nearly all wrist-worn devices. However, arm movements lead to the creation of Motion Artifacts (MA), affecting the accuracy of HR tracking using PPG sensors. This problem is commonly tackled by exploiting the recorded accelerometer data to correlate them with the PPG signal and eventually clean it. Thus, automatic fusion techniques based on Deep Learning (DL) algorithms have been proposed, but they are considered too large and complex to be deployed on wearable devices. The current work presents a novel and lightweight DL architecture, PULSE, improving sensor fusion by applying a multi-head cross-attention layer to the extracted temporal features. Moreover, we propose a relation-based knowledge distillation mechanism to pass PULSE's knowledge to a student network that uses modality-wise convolutions to replace the attention module and mimic the teacher's performance with 5× fewer parameters. The teacher and student are evaluated on two datasets: a) PPG-DaLiA the most extensive available dataset, with PULSE achieving close performance to the best state-of-the-art model, and b) WESAD with PULSE reducing the mean absolute error by 22.6%. The student model is further compressed using post-training quantization and deployed on two commercial-off-the-shelf microcontrollers, demonstrating its suitability for real-time execution, having a close-to-state-of-the-art MAE of 4.81 BPM (+0.40 BPM) on the PPG-DaLiA, but a 10.9× lower memory footprint of 37.9 kB, and consuming 45.9× lower energy (0.577 mJ).
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Location and Orientation of the Heart

