Related Experiment Video
Updated: Sep 19, 2025

A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Published on: July 20, 2022
Efficacy and safety of novel polyethersulfone dialyzers: a multicenter, randomized, crossover study
Seong Geun Kim1, Semin Cho2, Jin Kyung Kwon3
1Department of Internal Medicine, Inje University Sanggye Paik Hospital, Seoul, Republic of Korea.
Background:
The continuous rise in healthcare costs associated with hemodialysis has become a growing concern in South Korea, where hemodialysis is the predominant treatment modality for end-stage kidney disease. Currently, all dialyzers are imported, underscoring the need for domestically manufactured alternatives. This study aims to evaluate the clinical efficacy and safety of a domestically produced novel polyethersulfone dialyzer.
Methods:
This multicenter, randomized, crossover clinical trial evaluated the non-inferiority of the Synoflux series dialyzer (Synopex Inc.) compared to the commercially available FX Classix dialyzer (Fresenius Medical Care) in maintenance hemodialysis patients. Each patient was randomly assigned to one of two treatment sequences, receiving each dialyzer for 4 weeks in a crossover design. The primary endpoints were the urea reduction ratio (URR) and single-pool Kt/V (spKt/V). Secondary endpoints included the clearance of middle molecules and safety outcomes.
Results:
The Synoflux series dialyzer met the non-inferiority criteria for both URR (mean difference, -1.29%; 95% confidence interval [CI], -2.01 to -0.58) and spKt/V (mean difference, -0.06; 95% CI, -0.10 to -0.02). It demonstrated superior clearance of middle-molecule solutes, including cystatin C, β2-microglobulin, and prolactin. No serious adverse events related to the dialyzer were reported, and the frequency of hypotension or clotting events was comparable between the dialyzers.
Conclusion:
The Synoflux series dialyzer demonstrated non-inferior efficacy and acceptable safety compared to the widely used FX Classix dialyzer, thereby supporting its clinical applicability as a domestically produced alternative for maintenance hemodialysis.
More Related Videos
07:11Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Related Concept Videos
Hemodialysis II: Procedure and Complications
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Peritoneal Dialysis I: Introduction and Procedure
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Dialysis
Peritoneal Dialysis III: Nursing Management