Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
Automatic contour quality assurance using deep-learning based contours
Barbara Marquez1,2, David Fuentes2,3, Christine B Peterson2,4
1Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.
None:
Objective.Safe deployment of auto-contouring models requires the inclusion of automated quality assurance (QA). One such approach is to use two independent auto-contouring models and compare them geometrically for acceptability. This is not effective because geometric differences may not correlate with clinically significant errors. Herein, we investigated whether a two-contour QA system is improved by including dose in this comparison.Approach.Volumetric modulated arc therapy plans were generated for 86 head and neck (H&N) and 50 cervical (GYN) cancer patients, using clinically-approved planning target volumes (PTVs) and auto-contour organs-at-risk (OARs) from a primary auto-contouring model. Doses to the primary OARs were compared with doses to manually drawn and approved OARs ('the truth'). A difference inDmeanorDmax⩾ 2 Gy was identified as a reporting error (Derror). A second, independent auto-contouring model was then used to contour the OARs (verification). The primary and verification auto-contouring models were compared geometrically (dice similarity coefficient (DSC), surface DSC, 95% Hausdorff distance, mean surface distance) and dosimetrically (Dmean,Dmax). The ability of comparison metrics between the two auto-contouring models to flag actual dosimetric errors (i.e. primary model compared with the truth) was investigated. A logistic regression model was used to predictDerror. The data was divided by disease site and into 50/50 stratified training and testing sets;k-fold cross validation was employed during training to avoid overfitting. H&N structures were further divided into size-specific groups to improve model performance and generalizability.Main results.Including dose metrics in the logistic regression model to predictDerror, meanincreased the performance in terms of receiver-operating characteristic curve-area under the curve and area under the precision-recall curve in the test set for H&N small structures. ForDerror, max, including dose metrics increased performance for H&N small structures, H&N medium structures, and GYN structures.Significance.In many instances, utilizing dose with geometric comparisons can improve the ability of a verification model to flag potential errors from a primary auto-contouring model.
Related Concept Videos
Topographic Surveying and Contours
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...