Related Experiment Video
Updated: May 5, 2026

11:53
Spatial Multiobjective Optimization of Agricultural Conservation Practices using a SWAT Model and an Evolutionary Algorithm
Published on: December 9, 2012
13.1K
Retraction notice to "Forecasting the transportation energy demand with the help of optimization artificial neural
Yijie Liu1, Gongxing Yan2,3, Andrea Settanni4,5
1Chongqing Creation Vocational College, Yongchuan 402160, Chongqing, China.
Heliyon
|June 19, 2025
Abstract:
[This retracts the article DOI: 10.1016/j.heliyon.2023.e21599.].
Related Concept Videos
Energy to Drive Translocation
2.0K
Mitochondrial protein import is powered by two distinct energy sources: ATP hydrolysis and electrochemical potential across the inner membrane. Newly synthesized precursors are bound by cytosolic chaperones of the Hsp70 family, which guide them to the import receptors on the mitochondrial surface. Utilizing the energy of ATP hydrolysis, Hsp70 chaperones transfer these precursors to the TOM receptors on the mitochondrial outer membrane.
Generally, polypeptides are unfolded by two distinct...
Generally, polypeptides are unfolded by two distinct...
2.0K
Net Torque Calculations
9.3K
When a mechanic tries to remove a hex nut with a wrench, it is easier if the force is applied at the farthest end of the wrench handle. The lever arm is the distance from the pivot point (the hex nut in this case) to the person’s hand. If this distance is large, the torque is higher. Only the component of the force perpendicular to the lever arm contributes to the torque. Therefore, pushing the wrench perpendicular to the lever arm is more advantageous. If multiple people apply force to...
9.3K
Energy Losses in Transformers
1.6K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.6K
Energy Conservation and Bernoulli's Equation
7.2K
Applying the conservation of energy principle or the work-energy theorem to an incompressible, inviscid fluid in laminar, steady, irrotational flow leads to Bernoulli's equation. It states that the sum of the fluid pressure, potential, and kinetic energy per unit volume is constant along a streamline.
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
7.2K
Reducing Line Loss
524
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
524
Energy Line and Hydraulic Gradient Line
2.9K
Based on Bernoulli's equation, the energy line (EL) and hydraulic grade line (HGL) provide graphical representations of energy distribution in a fluid flow system. For steady, incompressible, inviscid flows, Bernoulli's equation is expressed as:
2.9K

