Related Experiment Video
Updated: Sep 19, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Difference in laxity between single- and multi-radius total knee arthroplasty implants is greatest in extension when
Enrico M Forlenza1, Alexander D Orsi2, Christopher Plaskos2
1Department of Orthopaedic Surgery, Rush University Medical Center, Il, USA.
Background:
This study quantified the relative impact of single-vs multi-radius femoral implant designs on coronal ligament laxity throughout flexion when gap planning at 10 and 90° flexion. These changes in laxity were also compared to those resulting from a change in the implant alignment technique.
Methods:
One hundred fifty-four consecutive robotic-assisted TKAs performed with a robotic ligament tensioning device, a cruciate-retaining single-radius (SR) femoral implant and an inverse kinematic alignment (iKA) technique were reviewed. Intraoperative data from each case was used to simulate implantation of a multi-radius (MR) implant of equivalent size, aligning both implants at 10 and 90° flexion to achieve a balanced knee. A mechanical alignment (MA) technique with SR implant was also simulated. Average mediolateral (ML) laxity and balance throughout flexion were compared for SR vs. MR and for iKA vs. MA.
Results:
At 0° (extension) the SR implant had 0.7 mm greater laxity than MR, while at 20° and 30° flexion SR had 0.4 mm less laxity medially and laterally. The difference in laxity between the two systems was ≤0.2 mm beyond 45° flexion. The difference in average ML laxity for MA vs iKA was greater than the difference in laxity due to SR vs MR throughout flexion (p < 0.001), with mean differences ranging from 1.3 to 1.7 mm between alignment techniques.
Conclusion:
When aligning SR and MR implants to achieve balance at 10° of flexion, SR will have more laxity at full extension (0°) and less laxity in early flexion and mid-flexion (20-40° flexion) compared to MR. The laxity difference in extension is almost 1 mm and may be clinically apparent. Surgeons should be aware of the difference in laxity profiles when using implants of different designs. These differences however are less than those encountered when changing alignment technique from MA to iKA.
More Related Videos
Related Concept Videos
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Angle of Twist - Elastic Range
Normal Strain under Axial Loading
Eccentric Axial Loading in a Plane of Symmetry
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...