Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Inconclusive Single-Lead ECGs From Smart-Devices: Impact of Baseline ECG Anomalies
Corinne Isenegger1, Diego Mannhart1, Simon Weidlich1
1Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, University of Basel, Basel, Switzerland.
Background:
Multiple smart devices can record single-lead electrocardiograms (SL-ECGs) with automated rhythm classification. The impact of pre-existing baseline ECG anomalies on the accuracy of automated rhythm classification remains largely unknown.
Objectives:
This study sought to compare the presence of predefined ECG anomalies and their impact on rhythm classification ability of 5 commercially available FDA and CE-marked wearable smart-devices.
Methods:
This prospective study included consecutive patients undergoing electrophysiological procedures at a tertiary referral center. Each participant obtained a 12-lead ECG followed by SL-ECGs with 5 different smart devices (AliveCor KardiaMobile, Apple Watch 6, Fitbit Sense, Samsung Galaxy Watch 3, and Withings ScanWatch). Two independent cardiologists performed manual rhythm classification and assessed the following ECG anomalies: ventricular pacing, conduction delay, low voltage, artifacts, and premature atrial or ventricular complexes.
Results:
A total of 256 participants were included (29% female, mean age 66 years) generating 1,280 recorded SL-ECGs. Of these, 242 SL-ECGs (19%) were classified as inconclusive by at least 1 smart device. The presence of any ECG anomaly was significantly higher in inconclusive vs conclusive SL-ECGs, with 74% vs 42%; P < 0.001. ORs with 95% CIs for inconclusive classification by ECG anomaly were ventricular pacing 6.35 [3.84-10.61], conduction delay 2.42 [1.82-3.22], low voltage 2.37 [1.75-3.21], minor artifact 1.72 [1.17-2.51], major artifact 10.62 [6.78-16.99], premature atrial complex 2.23 [1.29-3.74], and premature ventricular complex 1.94 [1.29-2.89]. Notable differences were found between the assessed smart devices.
Conclusions:
Automated rhythm classification is highly susceptible to baseline ECG anomalies. This study provides insights into the most appropriate patient population for smart device-based arrhythmia monitoring and offers guidance for selecting the optimal smart device tailored to individual patient characteristics.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Holter Monitor: 24-Hour Monitoring
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...