Related Experiment Video
Updated: Sep 19, 2025

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Accuracy and Precision of the SlateSafety BandV2 and CORE Devices in Estimating Resting and Moderate Hyperthermic
Normand A Richard1,2, Stephen S Cheung3, Victoria E Claydon1
1Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada.
Purpose:
Core temperature (Tcore) monitoring is used in the prevention of heat illnesses and for heat-acclimation purposes. We examined the accuracy and precision of 2 commercially available devices (BandV2 and CORE) that estimate Tcore versus rectal temperature.
Method:
Eight eumenorrheic females (V˙O2max: ∼41 mL·kg-1·min-1) completed 60 minutes of cycling in the follicular phase and the luteal phase over 2 separate cycles, wearing a minimally permeable clothing ensemble to amplify thermal load.
Results:
Both devices proved to be precise at rest and during exercise. Between duplicate follicular and luteal tests, the CORE device bias was 0.1400 (0.33) °C and 0.0331 (0.42) °C, and the BandV2 device bias was 0.0418 (0.18) °C and -0.0171 (0.21) °C. Compared with rectal temperature, accuracy was below our preestablished criterion of ±0.27 °C. At rest, the devices underestimated Tcore: BandV2, -0.2735 (0.25) °C, and CORE, -0.2746 (0.28) °C, and at the 55-minute time point, both devices overestimated Tcore: BandV2, +0.5117 (0.37) °C, and CORE, +0.3319 (0.43) °C. The delta increase in Tcore did not differ between menstrual-cycle phases.
Conclusions:
The BandV2 and CORE indirect sensors currently offer precise but not accurate estimates of Tcore.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...