Related Experiment Video
Updated: Sep 18, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Quantification of Endogenous Steroids and Hormonal Contraceptives in Human Plasma via Surrogate Calibration and
Min Su1, Bernhard Drotleff2, Tamara Janker1
1Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tuebingen, 72076 Tuebingen, Germany.
Abstract:
Quantifying endogenous and exogenous steroids at low concentrations in biological matrices remains a major analytical challenge. Immunoassay-based diagnostics are limited by cross-reactivity, particularly at low levels, prompting a shift toward (ultra)high-performance liquid chromatography-tandem mass spectrometry ((U)HPLC-MS/MS) for clinical applications. A key limitation for endogenous hormone quantification is the absence of a true blank matrix for external calibration. To address this, we developed a surrogate calibration method employing 1,2-dimethylimidazole-5-sulfonyl chloride (DMIS) derivatization for estrogens, enabling sensitive and selective quantification alongside nonderivatized steroids. Stable isotope-labeled surrogate calibrants and internal standards were used to achieve matrix-matched quantification within a clinically relevant range. Parallelism between analytes and surrogate calibrants was systematically verified in plasma across multiple calibration levels. The method was further optimized through the use of narrow-bore UHPLC columns and refined chromatographic conditions to enhance sensitivity and resolution for a broad analyte panel. Combined with efficient protein precipitation and 96-well plate-based solid-phase extraction, the developed assay achieves pg/mL-level quantification in human plasma with high precision and accuracy. This integrated approach uniquely combines surrogate calibration for endogenous steroids with external calibration for exogenous contraceptives, including sensitive DMIS-based derivatization for estrogens, enabling comprehensive hormonal profiling in a single run. Beyond its analytical scope, the method outlines a structured validation strategy, which is aligned with regulatory principles, and may therefore serve as a practical reference for future LC-MS/MS assays employing surrogate calibration.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013