Related Experiment Video
Updated: Sep 18, 2025

Identification of Rare Bacterial Pathogens by 16S rRNA Gene Sequencing and MALDI-TOF MS
Published on: July 11, 2016
Performance and workflow comparison of the VITEK MS PRIME and Bruker Biotyper MALDI-TOF MS systems
Rachel E Bosserman1, Nicole J Tarlton1, Kelly Alvarado1
1Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, Missouri, USA.
None:
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for rapid identification of bacteria and yeast in clinical labs. The VITEK MS PRIME ("PRIME") is the latest MALDI-TOF MS system from bioMérieux. This study evaluated PRIME's performance and workflow timing against the MALDI Biotyper CA System by Bruker ("Biotyper"). We compared a collection of 154 bacteria and yeast clinical isolates from various specimen types using three methods: Biotyper target with a toothpick, PRIME target with the PICKME nib, and PRIME target with a loop. Positive blood culture isolates were also analyzed using these methods, with high-experience (HEU, n = 300) and low-experience users (LEU, n = 50) after short (6-8 h) and routine (18-24 h) incubation on agar plates. Workflow timing, from sample processing to organism identification, was assessed to identify time savings. PRIME identified 96% (PICKME) and 95% (Loop) of challenge isolates to genus level, compared with Biotyper at 99%. Short incubation of positive blood culture isolates demonstrated similar species-level identification rates across all methods (Biotyper: 84%, PRIME PICKME: 80%, PRIME Loop: 81%), although more repeats were needed compared with routine incubation. No difference in species identification occurred between users for any method at short incubation (89%-91%, HEU, vs 79%-85% LEU). Single-target process times were comparable for all methods (55-59 min), whereas PRIME methods had shorter hands-on times for analysis of multiple targets (Biotyper: 53 min, PRIME PICKME: 39 min, PRIME Loop: 40 min). These findings highlight the comparable performance of the PRIME and Biotyper systems while demonstrating the potential for time savings with PRIME workflows, particularly in high-throughput settings.IMPORTANCEThis study provides a critical evaluation of the new VITEK MS PRIME MALDI-TOF MS system, comparing its performance and workflow efficiency against the Bruker MALDI Biotyper. The study investigates the success rate of isolate identification from short incubation of positive blood cultures, illustrating the utility of this technique for downstream workflows such as faster reporting of results for patient management and isolate identification for interpretation of rapid phenotypic AST. Analysis of different workflows demonstrated areas for potential time savings, particularly in high-throughput settings. These findings highlight the importance of optimizing MALDI-TOF MS workflows in the era of workforce shortages and lab centralization to enhance rapid pathogen identification and improve patient care.
More Related Videos
13:29Rapid Identification of Gram Negative Bacteria from Blood Culture Broth Using MALDI-TOF Mass Spectrometry
Published on: May 28, 2014
11:09Use of MALDI-TOF Mass Spectrometry and a Custom Database to Characterize Bacteria Indigenous to a Unique Cave Environment Kartchner Caverns, AZ, USA
Published on: January 2, 2015
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometers