Related Experiment Video
Updated: Sep 18, 2025

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Quantitative comparison of a novel swept-source optical coherence tomography angiography device with three
Michael Hafner1, Siegfried G Priglinger2, Bettina von Livonius2
1Department of Ophthalmology, LMU University Hospital, Ludwig-Maximilians-Universität München, Mathildenstraße 8, 80336, Munich, Germany. Michael.Hafner@med.uni-muenchen.de.
None:
Optical Coherence Tomography Angiography (OCTA) has become an essential non-invasive imaging technique for high-resolution visualization of retinal microvasculature. This study evaluates the performance of a novel Swept-Source OCTA device, Intalight DREAM, compared to established systems: Heidelberg Spectralis, Topcon Triton, and Zeiss Cirrus. We assessed acquisition time and microvascular parameters in the superficial (SCP) and deep (DCP) capillary plexuses using the OCTA Vascular Analyser algorithm for standardized image analysis across devices on 30 eyes from 15 healthy participants. In the SCP, DREAM demonstrated a higher median vessel length (47 μm) and greater fractal dimension (mean: 1.999) than the other devices, indicating enhanced continuity and network complexity. In the DCP, DREAM showed a smaller foveal avascular zone (median: 0.339 mm2) compared to Spectralis (0.51 mm2), Triton (0.5935 mm2), and Cirrus (0.9145 mm2), along with a smaller vessel diameter (median: 23 μm) compared to Triton and Cirrus. With a median imaging time of 9.1 s, DREAM was significantly faster than the Spectralis system (23.3 s) while providing largely comparable image quality, enhancing patient comfort, and potentially minimizing motion artifacts. These findings suggest that DREAM OCT is a promising tool for deep retinal imaging, with strong potential for clinical application and research.
More Related Videos
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography