Related Experiment Video
Updated: Sep 18, 2025

Direct-current Stimulation and Multi-electrode Array Recording of Seizure-like Activity in Mice Brain Slice Preparation
Published on: June 7, 2016
Development of a microelectrode array system for simultaneous measurement of field potential and glutamate release in
Aiko Hasegawa1, Naoki Matsuda1, Ikuro Suzuki1
1Department of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama Kasumicho, Taihaku-ku, Sendai, Miyagi, 982-8577, Japan.
Abstract:
Disorders of the central nervous system and complex side effects caused by abnormal neurotransmitter release have been widely reported. Simultaneous real-time measurement of neurotransmitter release and field potential (FP) could provide insights into the relationship between chemical signaling and neural electrical activity. In this study, we developed a microelectrode array (MEA) system capable of simultaneously recording FP and electrochemical (EC) signals. To enable neurotransmitter detection, we fabricated an enzyme-modified carbon nanotube (CNT)-MEA using glutamate oxidase (Glu-Ox) and horseradish peroxidase (HRP) immobilized in an osmium-based redox polymer. Glu-Ox catalyzes the oxidative deamination of glutamate to produce hydrogen peroxide (H2O2), which is then electrochemically reduced by HRP-Os, generating a current proportional to glutamate concentration. This dual-enzyme cascade provides high substrate specificity and efficient electron transfer under low overpotentials, enabling sensitive detection of glutamate at nanomolar levels. Using this system, we simultaneously recorded extracellular potentials and glutamate release from hippocampal brain slices. Following caffeine administration, we observed both enhanced oscillatory FP activity and time-correlated increases in glutamate release. Furthermore, we also achieved the recording of dopamine release from brain slices using this system. These results confirm that the enzyme-modified CNT-MEA and integrated FP/EC recording platform enable real-time, simultaneous monitoring of neuronal activity and neurotransmitter dynamics. This technology provides a powerful tool for investigating neural circuit function, pathological mechanisms, and drug responses.
More Related Videos
10:24Recording and Modulation of Epileptiform Activity in Rodent Brain Slices Coupled to Microelectrode Arrays
Published on: May 15, 2018
06:28Author Spotlight: Unraveling Seizure Dynamics and Novel Therapeutics for Status Epilepticus Using CMOS High-Density Microelectrode Array Systems
Published on: September 27, 2024