Related Experiment Video
Updated: Jul 13, 2026

Dynamic Quantitative Sensory Testing to Characterize Central Pain Processing
Published on: February 16, 2017
Comparing Raynaud's phenomenon attack measurement tools: paper or smartphone application?
Rachel S Wallwork1, Haomin Hu2, Ami A Shah1
1Division of Rheumatology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Objective:
To compare two methods of recording Raynaud's Phenomenon (RP) attack frequency, duration and severity: the traditional Raynaud Condition Score (RCS) paper diary and a new smartphone application.
Methods:
We conducted a multicenter study of patients with stable SSc-RP. Participants were randomized to document their RP attacks in the RCS paper diary or smartphone application for one week, at which point they were again randomized to either continue the original recording method or cross over to the other recording method for an additional week. Participants who crossed over completed a questionnaire about their experience with each method. We compared patient preference, and RP documentation by recording method.
Results:
Fifty-five patients with stable SSc-RP were included. The 24 participants who used both modalities were significantly more likely to report "liking" the smartphone application than the paper diary (92% vs. 58%, p=0.04). There was also a non-significant difference in real-time documentation with the smartphone than the paper diary (71% vs. 38%, p=0.06). Participants reported significantly more attacks with the paper diary than with the smartphone application, however, the severity and average attack length were not significantly different.
Conclusion:
This study supports the use of a smartphone application to document RP attack frequency, duration and severity. Not only did patients prefer the smartphone application to the paper diary, but they were also more likely to record RP attacks in real-time with the smartphone application, reducing the risk of recall bias. Future clinical trials should consider using a smartphone-based application to capture RP attacks.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure

