Left ventricular systolic function and mechanical ventilation weaning failure: An updated systematic review and
Cristina Santonocito1, Simone Messina2, Mateusz Zawadka3
1Department of Anesthesia and Intensive Care, A.O.U. "Policlinico-San Marco", 95123 Catania, Italy.
Left ventricular systolic dysfunction (LVSD) is linked to weaning failure, but the association is weak and potentially not clinically significant. Diastolic dysfunction markers, however, consistently predict weaning failure.
Area of Science:
- Cardiology
- Critical Care Medicine
- Pulmonary Medicine
Background:
- Left ventricular (LV) systolic dysfunction's impact on weaning from mechanical ventilation remains uncertain.
- Echocardiographic parameters are crucial for assessing cardiac function in critically ill patients.
Purpose of the Study:
- To conduct an updated meta-analysis on the association between LV ejection fraction (LVEF) and weaning failure.
- To evaluate other echocardiographic parameters, including diastolic function, in relation to weaning outcomes.
Main Methods:
- Systematic search of MEDLINE and EMBASE for prospective studies.
- Inclusion of studies reporting weaning outcomes and echocardiographic data prior to spontaneous breathing trial (SBT).
- Meta-analysis of LVEF, E/e' ratio, E velocity, deceleration time, and e' velocity.
Main Results:
- Lower LVEF was associated with weaning failure (MD: -4.71), though with low certainty and not robust on trial sequential analysis.
- Higher E/e' ratio (MD: 1.90), increased E velocity (MD: 8.32), and shorter deceleration time (MD: -12.01) were significantly associated with weaning failure.
- e' velocity did not show a significant association with weaning failure (MD: -0.59).
Conclusions:
- A fragile association between poorer LV systolic function (LVEF) and weaning failure was identified, likely not clinically relevant.
- Elevated E/e' ratio and other diastolic parameters are confirmed predictors of weaning failure.
- e' velocity is not a reliable predictor of weaning failure in this context.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mitral Stenosis I: Introduction
Mechanical Ventilation I: Indication and Settings
Heart Failure II: Pathophysiology
Mitral Regurgitation I: Introduction