Related Experiment Video
Updated: Sep 18, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Technical note: modified method for utilizing the Farabeuf clamp in pelvic and acetabulum fracture fixation,
Amit Davidson1,2, Emmanuele Santolini3, Nikolaos K Kanakaris3
1Shaare Zedek Medical Center, Jerusalem, Israel. amitedavidson@gmail.com.
None:
Pelvic fracture fixation poses significant challenges due to limited exposure of the fracture site and the interference of reduction instruments with optimal placement of fixation plates. The ideal anatomical position for plate fixation is often occupied by reduction clamps, complicating the surgical process-particularly when using the Farabeuf clamp. While the Farabeuf clamp is a common tool in pelvic fracture surgery, this technical note introduces a modified technique for its application. This approach allows for simultaneous fracture reduction and plate placement, effectively restructuring the fixation process into a single-step procedure.