In vivo evaluation of root canal disinfection using a combination of ultrasonic activation and diode laser therapy
Related Experiment Video
Updated: Jun 21, 2026

Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
Sonali H Bansode1, Dayanand G Chole1, Srinivas S Bakle1
1Department of Conservative Dentistry and Endodontics, Pandit Deendayal Upadhyay Dental College, Solapur, Maharashtra, India.
Aim:
In vivo evaluation of root canal disinfection using a combination of ultrasonic activation and diode laser therapy.
Objective:
The primary aim of this study was to evaluate the effectiveness of ultrasonic activation of sodium hypochlorite and diode laser irradiation in enhancing root canal disinfection by reducing bacterial load.
Materials And Methods:
Thirty patients aged 20-60 years with necrotic lower premolars and periapical infections were selected. After access opening, initial microbial samples (S1) were collected. The canals were then instrumented using ProTaper Next rotary files and irrigated with 2.5% sodium hypochlorite, which was activated ultrasonically using EndoX for 1 min. The second microbial sample (S2) was collected. Subsequently, 980 nm diode laser irradiation was applied in a pulsed mode, and the final microbial sample (S3) was obtained. All the samples were cultured in Brain Heart Infusion Agar (BHI) agar, and colony-forming units (CFU/ml) were determined. Statistical analysis was performed using the SPSS software with a significance threshold of P ≤ 0.05.
Results:
The mean CFU/ml count significantly reduced from S1 (22.93) to S2 (6.03) after ultrasonic activation and further decreased to S3 (1.04) following diode laser application. The reduction was statistically significant (P < 0.001).
Conclusion:
The combination of ultrasonic activation of sodium hypochlorite and diode laser irradiation significantly enhances root canal disinfection. Ultrasonic activation improves irrigant penetration, while diode laser provides deeper antimicrobial action.
More Related Videos
06:06Adjunctive Diode Laser Therapy and Probiotic Lactobacillus Therapy in the Treatment of Periodontitis and Peri-Implant Disease
Published on: May 9, 2022
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Treating Helicobacter pylori in Peptic Ulcers: Antimicrobial Therapy
Physical Methods for Controlling Microbial Growth: Radiation and Filtration