Efficient Acoustic Thermometry Method for Power Plant Boilers Based on the LMS Quadratic Cross-Correlation
Jidong Yan1, Liansuo An1, Guoqing Shen1
1School of Energy, Power and Mechanical Engineering, North China Electric Power University, 102206 Beijing, China.
Abstract:
Aiming to achieve an accurate time delay estimation in acoustic thermometry for power plant boilers, this study proposes a time delay estimation algorithm that combines the least-mean-square (LMS) adaptive filtering algorithm and generalized quadratic cross-correlation. First, numerical simulations are conducted, followed by the experimental study performed both in a laboratory environment and on a 750 tons/day waste incineration boiler test platform. In addition, the proposed algorithm is compared with a generalized quadratic cross-correlation algorithm. The results show that the LMS quadratic cross-correlation algorithm can effectively filter out noise under both numerical simulation and laboratory conditions. The results also indicate that in a harsh environment of power plant boilers, the proposed algorithm can achieve accurate time delay estimation, significantly improving the accuracy of single-path acoustic temperature measurement.
More Related Videos
10:29Experimental Methodology for Estimation of Local Heat Fluxes and Burning Rates in Steady Laminar Boundary Layer Diffusion Flames
Published on: June 1, 2016
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermodynamics: Activity Coefficient
The activity coefficient is a measure of the deviation from ideal behavior. When the ionic strength of the solution is minimal, the activity coefficient of an ionic species is close to unity, making...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Quantifying Heat
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...