Related Experiment Video
Updated: Sep 18, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination
Hikari Tsukamoto1,2, Hiroshi Muraishi1, Ryoji Enomoto1
1School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan.
Abstract:
In this study, we developed an omnidirectional rotating Compton camera that was capable of imaging low-level radioactive contamination caused by 177Lu-oxodotreotide, a novel radiopharmaceutical that has recently been attracting attention in nuclear medicine. The detector employs a compact design that comprises only six scintillator crystals mounted on a motorized rotating stage. By optimizing the crystal type and size, and optimizing the interval between crystals, the detector is able to adapt to a wide range of environmental conditions, including observable gamma-ray energies, dose rates, and angular resolution. Monte Carlo simulations using Geant4 were conducted to optimize the configuration of the detector. Based on the results of the simulation, a prototype detector using six 3.5 cm cubic [Formula: see text] crystals was developed for visualizing 177Lu-contaminated sites. The experimental results demonstrated that the detector could successfully visualize an unsealed 177Lu -oxodotreotide source with high sensitivity without being affected by gamma rays from 99TC, which is also present in nuclear medicine facilities. The developed rotating Compton camera technology is anticipated to serve as a reliable environmental monitoring tool in nuclear medicine facilities. Through its ability to rapidly detect radioactive contamination, this detector has the potential to reduce the radiation exposure risks for both medical professionals and the general public.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
X-ray Imaging