Related Experiment Video
Updated: Sep 18, 2025

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Three-Dimensional Mechanical Characterization of Normal, Subclinical, and Keratoconic Corneas Using Motion Tracking
J Bradley Randleman1, Hongyuan Zhang2, Bassel Hammoud2
1From the Cole Eye Institute (J.B.R., H.Z., B.H., B.A.L.D., B.N.S.), Cleveland Clinic, Cleveland, Ohio, USA; Cleveland Clinic Lerner College of Medicine of Case Western Reserve University (J.B.R.), Cleveland, Ohio, USA.
Purpose:
To characterize the 3-dimensional (3-D) mechanical differences between normal corneas and those with subclinical keratoconus (SKC) or clinical keratoconus (KC) using motion-tacking (MT) Brillouin microscopy.
Design:
Prospective cross-sectional study.
Methods:
There were 50 eyes from 50 patients evaluated, including 20 Control eyes from 20 patients, 20 SKC eyes from 20 patients, and 10 stage I or II KC eyes from 10 patients. All patients had Scheimpflug imaging for group classification and MT Brillouin microscopy using a custom-built device for mechanical evaluation. Mean and minimum MT Brillouin shift values were generated in the anterior, middle, and posterior stromal regions. Receiver operating characteristic (ROC) curves were generated for MT Brillouin metrics to determine the area under the ROC curve (AUROC), sensitivity, and specificity for each variable at each location.
Results:
There were no significant differences between groups for age, sex, or mean keratometry. There were significant differences between control, SKC, and KC groups for all MT Brillouin metrics, with greatest differences in anterior min (Δ 43-57 MHz, P < .001) and Mean (Δ 34-37 MHz, P < .001), middle min (Δ 44-69 MHz, P < .001) and Mean (Δ 39-54 MHz, P < .001), and least differences in posterior min (Δ 15-22 MHz, P < .001) and Mean (Δ 20-32 MHz, P < .001). Anterior min values fully separated both SKC and KC groups from controls (AUC = 1.0 for each), while anterior mean (AUC = 0.98, 1.0), middle mean (AUC = 0.96, 1.0), and middle min (AUC = 0.94, 1.0) performed better than posterior mean (AUC = 0.81, 0.95) or posterior min (AUC = 0.78, 0.88).
Conclusions:
MT Brillouin microscopy identified 3-dimensional differences between controls eyes and those with subclinical or early-stage keratoconus. Differences were most pronounced in the anterior stroma and least pronounced in the posterior stroma, indicating relevant axial mechanical differences in eyes with SKC. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.
More Related Videos
11:29Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
Published on: January 3, 2011
05:51Author Spotlight: Non-Contact Measurement of Tissue Mechanics in Live Chick Embryos Using Brillouin Microscopy
Published on: November 10, 2023
Related Concept Videos
Three-Dimensional Microscopy in Microbiology
Mechanism of Ciliary Motion
The cilia are made up of microtubules in a 9+2 arrangement, with nine microtubule doublet ring bundles, surrounding a pair of central singlet microtubule bundles. The doublet microtubule bundles are...