Related Experiment Video
Updated: Sep 18, 2025

Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
Rapid elemental imaging of copper-bearing critical ores using laser-induced breakdown spectroscopy coupled with PCA
Amir Fayyaz1, Muhammad Waqas2, Haroon Asghar3
1National Centre for Physics, Quaid-i-Azam University Campus, Islamabad, 45320, Pakistan; Atomic and Molecular Physics Laboratory, Department of Physics, Quaid-i-Azam University, Islamabad, 45320, Pakistan.
Abstract:
This study presents the application of laser-induced breakdown spectroscopy (LIBS) for analyzing various copper-bearing critical ores with significant Cu concentrations. LIBS detected Cu as a base element, along with other minor elements including Al, C, Fe, Mg, Ni, Si, and Zn, under optimized experimental conditions that include 80 ± 0.3 mJ laser energy, 2 μs delay time, ∼500 μm spot size, and a 45° angle between the collecting lens and the sample surface. The energy-dispersive X-ray technique was employed to determine the elemental concentrations and spatial distributions within the sample, based on Kα, Kβ, and Lα characteristic lines. Quantitative analysis in LIBS is challenging due to matrix effects on line intensities, often requiring matrix-matched standards; however, the multielemental quality of LIBS spectra enables the detection of matrix types for accurate classification. In this contribution, we applied an unsupervised principal component analysis (PCA) on pre-processed LIBS data to reduce dimensionality and visualize clusters, showing that the first three principal components (PCs) account for 97.9 % of the total variance (PC1: 69.8 %, PC2: 20.3 %, PC3: 7.8 %). Elliptical PCA clustering with a 96 % confidence interval was achieved using SIMCA. A supervised partial least squares-discrimination analysis model is used to identify the variables that contribute most to classification. The model yields cumulative X and Y variances of 97.86 % and 99.96 %, respectively, with an R2 range of 0.83-0.99 across the first 6 factors. Furthermore, LIBS 2D mapping is carried out using Cu spectral lines at 510.6 (2P3/2 → 2D5/2), 515.3 (2D3/2 → 2P1/2), and 521.8 nm (2D5/2 → 2P3/2), and Zn at 481.1 nm (3S1 → 3P2), over 50 and 200 scans to visualize the element spatial distribution. Mapping is cross-validated using Pearson's correlation covering a 50 × 50 mm2 area, achieving ∼150 μm spatial resolution and an average root mean PRESS of ∼94 % with a high correlation of ∼0.989. The results show the efficiency of LIBS integrated with multivariate methods for pattern recognition, classification, and spatial analysis in the exploration of copper ores.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview