Comparing Occupational Exposure from 18F-FDG Injection Procedure Using a Traditional Injection Method Versus an
Raju Gupta1, Shantanu Pande2, Ashwini P Shinde2
1Department of Nuclear Medicine, All India Institute of Medical Sciences Nagpur, Maharashtra, India rajugupta0893@gmail.com.
None:
We evaluated occupational radiation exposure associated with 18F-FDG injection using a traditional manual approach versus an automated injection system. Methods: Wrist and whole-body radiation exposure of nuclear medicine personnel using a manual injection method versus an automated injection system for 18F-FDG administration were assessed using electronic personal dosimeters. Radiation exposure while configuring both systems was also evaluated. The dose administered met the requirements of the "as low as reasonably achievable" principle. Radiation exposure during initial setup and dose administration, residual activity, dose accuracy, presence of contamination, and frequency of extravasation were compared between methods. Results: Compared with the traditional manual method, use of the automated injection system resulted in significantly lower mean radiation exposure to medical physicists' wrists (P < 0.01). Radiation exposure was 79.41% lower at the wrist while using the automated injection system. Differences in whole-body radiation exposure were not significant between injection methods (P < 0.56). The overall radiation dose per injection at the wrist and in the whole body and mean residual activity after injection were noticeably lower with the automated system (P < 0.01), with mean residual activity decreasing by 73.58%. Conclusion: The overall radiation exposure for nuclear medicine personnel was significantly decreased when administering 18F-FDG via an automated injection system.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET