Related Experiment Video
Updated: Sep 18, 2025

04:36
Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
2.3K
Proposed Standards for the Use of CO2 in Dialysis Access Interventions
Richard Tippett1, Robert Morgan2
1Dorset County Hospital NHS Foundation Trust, Dorchester, UK. richard.tippett@dchft.nhs.uk.
Cardiovascular and Interventional Radiology
|June 24, 2025
Abstract
No abstract available in PubMed .
More Related Videos
Related Concept Videos
Hemodialysis II: Procedure and Complications
146
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
146
Assessment of Diffusion and Perfusion
1.1K
Understanding and evaluating diffusion and perfusion is critical in assessing a patient's respiratory and circulatory health. These processes play key roles in maintaining the body's internal environment, ensuring that tissues receive adequate oxygen while waste products are efficiently removed.
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
1.1K
Hemodialysis III: Nursing Management
215
The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
215
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
111
Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
111
Peritoneal Dialysis I: Introduction and Procedure
232
Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
232
Peritoneal Dialysis III: Nursing Management
159
Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
159

