Related Experiment Video
Updated: Sep 18, 2025

06:02
Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
190
From TAVR to TTVR: Echoes of Progress and Caution
Mohamad Alkhouli1, Kuan-Chih Huang2
1Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.
JACC. Cardiovascular Interventions
|June 25, 2025
Abstract
No abstract available in PubMed .
Keywords:
conduction disorderleaflet thrombosisright ventricular functiontranscatheter valve replacementtricuspid regurgitationMore Related Videos
Related Concept Videos
Tracheostomy Care I: Pre-procedural Steps
401
A tracheostomy is a surgical technique that involves making an incision in the neck to provide access to the trachea. It is frequently used in medical conditions such as airway obstruction and prolonged mechanical ventilation. Effective nursing management is crucial for the long-term success of a tracheostomy.
Required Equipment
The equipment necessary for tracheostomy care includes:
Required Equipment
The equipment necessary for tracheostomy care includes:
401
Aortic Regurgitation III: Medical Management
53
Aortic regurgitation (AR) is when the aortic valve does not close or seal properly, leading to backward blood circulation from the aorta into the left ventricle during diastole. Common causes of AR include rheumatic heart disease, congenital valve defects, and aortic root dilation. Managing AR requires a multifaceted approach to alleviate symptoms, preserve left ventricular function, and address the underlying cause of the regurgitation. Patients with symptomatic AR or significant left...
53
Cardiac Catheterization I: Pre-Procedure Overview
178
Cardiac catheterization is an invasive diagnostic technique used to identify and evaluate structural and functional diseases of the heart and major blood vessels. This technique diagnoses congenital heart disease, coronary artery disease, valvular heart disease, and coronary spasms and assesses ventricular function. It helps guide treatment decisions, including the need for revascularization procedures like percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) and...
178
Ventilatory Modes
468
Mechanical ventilators are life-saving devices that support or replace spontaneous breathing. They deliver breaths to patients through varying methods known as ventilator modes. Understanding these modes is critical for healthcare providers managing patients with respiratory failure.
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
468
Tracheostomy Suctioning I: Pre-Procedural Steps
1.1K
Tracheostomy suctioning is a critical procedure healthcare professionals perform to maintain a patent airway in patients with a tracheostomy tube. This procedure is necessary when secretions accumulate in the airway, causing respiratory distress. Here is a step-wise procedural guide for performing tracheostomy suctioning using an open system.
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
1.1K
Adjusting a Traverse
110
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
110

