Related Experiment Video
Updated: Sep 18, 2025

Stem Cell Transplantation Strategies for the Restoration of Cognitive Dysfunction Caused by Cranial Radiotherapy
Published on: October 18, 2011
Dosimetric Study of Biaxially Rotational Dynamic Radiation Therapy for Hippocampal-Sparing Whole Brain Irradiation
Kouta Hirotaki1, Kenji Makita2,3, Masaki Nakamura2
1Department of Radiological Technology, National Cancer Center Hospital East, Chiba 277-8577, Japan.
Abstract:
Objectives: Although hippocampal-sparing whole-brain irradiation (HS-WBI) offers potential neurocognitive benefits, it poses challenges in treatment planning. This study aimed to compare the dose distributions of biaxially rotational dynamic radiation therapy (BROAD-RT) with a novel O-ring-type linear accelerator (OXRAY) and conventional non-coplanar volumetric modulated arc therapy (VMAT) planning (Conv-VMAT) in HS-WBI treatment plans. Methods: This study included 10 patients with brain metastases from lung cancer at our institution. The hippocampus was contoured using gadolinium-based contrast-enhanced magnetic resonance imaging, and hippocampal-sparing regions were created using a 5 mm margin around the hippocampus. Two virtual plans (BROAD-RT and Conv-VMAT) with 30 Gy in 10 fractions were created to compare the dose distributions in the planning target volume (PTV), hippocampus, eyes, and lens. All plans were analyzed using a paired t-test. Results: The mean (standard deviation [SD]) hippocampus-Dmax, -Dmean, -D100%, and -V10 were 11.10 (0.61), 7.95 (0.20), 7.01 (0.19), and 0.42 (0.34) for BROAD-RT and 16.10 (0.57), 9.89 (0.75), 8.24 (0.34), and 39.05 (25.89) for Conv-VMAT, respectively. All hippocampal parameters were significantly better with BROAD-RT than with Conv-VMAT (p < 0.01). The PTV-D98, -D50, -D2, -V35, and -homogeneity index did not exhibit significant differences between BROAD-RT and Conv-VMAT. Although lens-Dmax was significantly better in BROAD-RT than in Conv-VMAT (p < 0.01), no significant differences were observed in the eye-Dmax and chiasm-Dmax between BROAD-RT and Conv-VMAT. The mean (SD) BROAD-RT beam delivery time was 313.60 (34.91) s. Conclusions: BROAD-RT improved hippocampal sparing with acceptable PTV coverage and PTV homogeneity in HS-WBI planning. In addition, BROAD-RT has a clinically acceptable treatment duration.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017